-- SCCS version: "@(#)att_sip.mib 4.1.2.2" -- -- Copyright 1992 AT&T -- All Rights Reserved -- -- NOTICE -- ------ -- The information in this document is subject to change -- without notice. AT&T assumes no responsibility for -- any errors that may appear in this document. -- -- Notwithstanding any other lease or license agreement -- that may pertain to, or accompany the delivery of, -- this computer software, the rights of the Government -- regarding its use, reproduction and disclosure are as -- set forth in Government contract no. GS00K89AGS6495. -- -- -- Title: AT&T SIP MIB for Customer Network Management -- ATT-CNM-SIP-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, Gauge FROM RFC1155-SMI DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212; -- -- Object Identifiers -- att-2 OBJECT IDENTIFIER ::= { enterprises 74 } att-products OBJECT IDENTIFIER ::= { att-2 1 } att-mgmt OBJECT IDENTIFIER ::= { att-2 2 } att-cnmAgent OBJECT IDENTIFIER ::= { att-products 9 } att-cnm OBJECT IDENTIFIER ::= { att-mgmt 15 } att-cnm-sip OBJECT IDENTIFIER ::= { att-cnm 5 } -- -- NOTE: -- All representations of SMDS addresses in this MIB module -- use, as a textual convention (i.e.,this convention does -- not affect their encoding), the data type: -- SMDSAddress ::= OCTET STRING(SIZE(8)) -- -- SMDSAddress is the 60-bit SMDS address, preceded by -- 4 bits with the following values: -- "1100" when representing an individual address -- "1110" when representing a group address -- -- -- the SIP group of objects (att-cnm-sip) include: -- -- the SIP Configuration table -- the SIP Measurements table -- the SIP Level 3 Error Log table -- -- the SIP Configuration table -- -- This table provides configuration information -- the SIP interfaces supported by this system. -- attCNMsipConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF AttCNMsipConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of entries containing configuration information for all SIP interfaces managed by this system." ::= { att-cnm-sip 1 } attCNMsipConfigEntry OBJECT-TYPE SYNTAX AttCNMsipConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing configuration information for a particular SIP interface." INDEX { attCNMsipConfigIndex } ::= { attCNMsipConfigTable 1 } AttCNMsipConfigEntry ::= SEQUENCE { attCNMsipConfigIndex INTEGER, attCNMsipMeasMaxIntervals INTEGER, attCNMsipMeasIntervalLen INTEGER } attCNMsipConfigIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each SIP interface. The interface identified by a particular value of this index is the same interface as identified by the same value of an attCNMifConfigIndex object instance." ::= { attCNMsipConfigEntry 1 } attCNMsipMeasMaxIntervals OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable identifies the maximum number of measurement intervals supported for the measurements maintained by this SIP interface in the attCNMsipMeasTable." ::= { attCNMsipConfigEntry 2 } attCNMsipMeasIntervalLen OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable identifies the number of seconds that make up one complete measurement interval for the measurements maintained by this SIP interface in the attCNMsipMeasTable." ::= { attCNMsipConfigEntry 3 } -- the SIP Measurements table -- -- This table provides counts on the various traffic -- measurements maintained by a SIP interface during -- the specified measurement interval. -- attCNMsipMeasTable OBJECT-TYPE SYNTAX SEQUENCE OF AttCNMsipMeasEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of entries containing traffic measurements, maintained during the specified measurement interval, for all SIP interfaces managed by this system." ::= { att-cnm-sip 2 } attCNMsipMeasEntry OBJECT-TYPE SYNTAX AttCNMsipMeasEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing traffic measurements, maintained during the specified measurement interval, for a particular SIP interface." INDEX { attCNMsipMeasIndex, attCNMsipMeasInterval } ::= { attCNMsipMeasTable 1 } AttCNMsipMeasEntry ::= SEQUENCE { attCNMsipMeasIndex INTEGER, attCNMsipMeasInterval INTEGER, attCNMsipMeasTimeStamp INTEGER, attCNMsipMeasLocalTime DisplayString, attCNMsipReceivedL3PDUs Gauge, attCNMsipSentL3PDUs Gauge, attCNMsipReceivedGroupL3PDUs Gauge, attCNMsipSentGroupL3PDUs Gauge, attCNMsipReceivedL2PDUs Gauge, attCNMsipSentL2PDUs Gauge } attCNMsipMeasIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each SIP interface. The interface identified by a particular value of this index is the same interface as identified by the same value of an attCNMifConfigIndex object instance." ::= { attCNMsipMeasEntry 1 } attCNMsipMeasInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable identifies the measurement interval number for which measurement is provided. It is a number between 1 and XX, where 1 identifies the most recently completed measurement interval and XX is the least recently completed measurement interval. The value of XX is specified by the attCNMsipMeasMaxIntervals object given in the attCNMsipConfigTable. The maximum length of each measurement interval is specified by the attCNMsipMeasIntervalLen object given in the attCNMsipConfigTable." ::= { attCNMsipMeasEntry 2 } attCNMsipMeasTimeStamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The time stamp corresponding to the end of the specified measurement interval, as measured in seconds from 00:00:00 UTC (Coordinated Universal Time) January 1, 1970. Any fraction is rounded up." ::= { attCNMsipMeasEntry 3 } attCNMsipMeasLocalTime OBJECT-TYPE SYNTAX DisplayString(SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The time stamp corresponding to the end of the specified measurement interval. Any fraction is rounded up. It is given as a printable ASCII string showing the local time at the end of the interval." ::= { attCNMsipMeasEntry 4 } attCNMsipReceivedL3PDUs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of individual-addressed and group-addressed L3 PDUs received by a SIP interface during the specified measurement interval." ::= { attCNMsipMeasEntry 5 } attCNMsipSentL3PDUs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of individual-addressed and group-addressed L3 PDUs sent by a SIP interface during the specified measurement interval." ::= { attCNMsipMeasEntry 6 } attCNMsipReceivedGroupL3PDUs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of group-addressed L3 PDUs received by a SIP interface during the specified measurement interval." ::= { attCNMsipMeasEntry 7 } attCNMsipSentGroupL3PDUs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of group-addressed L3 PDUs sent by a SIP interface during the specified measurement interval." ::= { attCNMsipMeasEntry 8 } attCNMsipReceivedL2PDUs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of L2 PDUs received by a SIP interface during the specified measurement interval." ::= { attCNMsipMeasEntry 9 } attCNMsipSentL2PDUs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of L2 PDUs sent by a SIP interface during the specified measurement interval." ::= { attCNMsipMeasEntry 10 } -- the SIP Level 3 Error Log table -- -- This table provides a log of the latest occurrences -- of the various protocol errors encountered at the -- Level 3 layer of all SIP interfaces supported by this -- system. -- attCNMsipL3ErrorLogTable OBJECT-TYPE SYNTAX SEQUENCE OF AttCNMsipL3ErrorLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of entries identifying the latest occurrence of protocol errors encountered at the Level 3 layer of all SIP interfaces managed by this system." ::= { att-cnm-sip 3 } attCNMsipL3ErrorLogEntry OBJECT-TYPE SYNTAX AttCNMsipL3ErrorLogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry identifying the latest occurrence of a specific protocol error encountered at the Level 3 layer of a particular SIP interface." INDEX { attCNMsipL3ErrorLogIndex, attCNMsipL3ErrorLogType } ::= { attCNMsipL3ErrorLogTable 1 } AttCNMsipL3ErrorLogEntry ::= SEQUENCE { attCNMsipL3ErrorLogIndex INTEGER, attCNMsipL3ErrorLogType INTEGER, attCNMsipL3ErrorLogSA SMDSAddress, attCNMsipL3ErrorLogDA SMDSAddress, attCNMsipL3ErrorLogTimeStamp INTEGER, attCNMsipL3ErrorLogLocalTime DisplayString } attCNMsipL3ErrorLogIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each SIP interface. The interface identified by a particular value of this index is the same interface as identified by the same value of an attCNMifConfigIndex object instance." ::= { attCNMsipL3ErrorLogEntry 1 } attCNMsipL3ErrorLogType OBJECT-TYPE SYNTAX INTEGER { daFieldFormatError(1), saFieldFormatError(2), baSizeFieldValueInvalid(3), heLengthInvalid(4), heElementLengthInvalid(5), heVersionElementInvalid(6), heCarrierSelectionElementInvalid(7), hePADInvalid(8), beTagMismatch(9), baSizeFieldNotEqualLengthField(10), incorrectLength(11), mriTimeout(12) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of error. It could be one of: - Destination Address Field Format Error, - Source Address Field Format Error, - Invalid BAsize Field Value, - Invalid Header Extension Length, - Invalid Header Extension: Element Length, - Invalid Header Extension: Carrier Selection Element Format, - Invalid Header Extension: Carrier Selection Element Length, - Invalid Header Extension: Version Element Position, Length or Value, - BEtag Mismatch, - BAsize Field Not Equal To Length Field, - Incorrect Length, - MSS Receive Interval Timeout." ::= { attCNMsipL3ErrorLogEntry 2 } attCNMsipL3ErrorLogSA OBJECT-TYPE SYNTAX SMDSAddress ACCESS read-only STATUS mandatory DESCRIPTION "The SMDS source address in the rejected L3 PDU." ::= { attCNMsipL3ErrorLogEntry 3 } attCNMsipL3ErrorLogDA OBJECT-TYPE SYNTAX SMDSAddress ACCESS read-only STATUS mandatory DESCRIPTION "The SMDS destination address in the rejected L3 PDU." ::= { attCNMsipL3ErrorLogEntry 4 } attCNMsipL3ErrorLogTimeStamp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The time stamp for the latest occurrence of the specified error, as measured in seconds from 00:00:00 UTC (Coordinated Universal Time) January 1, 1970. Any fraction is rounded up." ::= { attCNMsipL3ErrorLogEntry 5 } attCNMsipL3ErrorLogLocalTime OBJECT-TYPE SYNTAX DisplayString(SIZE(0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The time stamp for the latest occurrence of the specified error. It is given as a printable ASCII string showing the local time at the latest occurrence of this type of error." ::= { attCNMsipL3ErrorLogEntry 6 } END