-- MIB File Generated on 31-Oct-1995 at 13:59:17 X25W-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, experimental, IpAddress, TimeTicks, Gauge, Counter FROM RFC1155-SMI DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212; usr OBJECT IDENTIFIER ::= { enterprises 429 } nas OBJECT IDENTIFIER ::= { usr 1 } x25w OBJECT IDENTIFIER ::= { nas 8 } x25wanAdmn OBJECT IDENTIFIER ::= { x25w 1 } x25wanAdmnTable OBJECT-TYPE SYNTAX SEQUENCE OF X25wanAdmnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The x25 WAN Admn table contains an entry for each manageable X.25 Subnet in the chassis. It provides a means to configure serial interface associated with the subnet." ::= { x25wanAdmn 1 } x25wanAdmnEntry OBJECT-TYPE SYNTAX X25wanAdmnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "There is one x25 WAN Cfg entry per x.25 subnet in the NAS chassis." INDEX { x25wanAdmnIndex } ::= { x25wanAdmnTable 1 } X25wanAdmnEntry ::= SEQUENCE { x25wanAdmnIndex INTEGER, x25wanAdmnType INTEGER, x25wanAdmnSpeed INTEGER, x25wanAdmnLinkAvailable INTEGER, x25wanAdmnClockSouce INTEGER, x25wanAdmnMaxFrmSize INTEGER } x25wanAdmnIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each X.25 Subnet in the chassis. The value of this object matches the value of the index of the corresponding X.25 Subnet's entry in the entity table of the chassis MIB." ::= { x25wanAdmnEntry 1 } x25wanAdmnType OBJECT-TYPE SYNTAX INTEGER{ rs232(1), v35(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines which physical serial interface type is implemented." ::= { x25wanAdmnEntry 2 } x25wanAdmnSpeed OBJECT-TYPE SYNTAX INTEGER (0..393216) ACCESS read-write STATUS mandatory DESCRIPTION "Defines the serial port speed used in applications where the Gateway NAC generates a clock. This object will not effect the clock speed when the host provides the clock source. Default=57600." ::= { x25wanAdmnEntry 3 } x25wanAdmnLinkAvailable OBJECT-TYPE SYNTAX INTEGER{ dsr(1), dcd(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines whether the WAN interface looks at DCD rather than DSR to determine that the physical layer is active." ::= { x25wanAdmnEntry 4 } x25wanAdmnClockSouce OBJECT-TYPE SYNTAX INTEGER{ dceRxTx(1), dceRxOnly(2), brgRxTx(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Determines the source of the synchronous data clock." ::= { x25wanAdmnEntry 5 } x25wanAdmnMaxFrmSize OBJECT-TYPE SYNTAX INTEGER (0..519) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the maximum received frame size allowed on the X.25 WAN. Default=300." ::= { x25wanAdmnEntry 6 } x25wanOper OBJECT IDENTIFIER ::= { x25w 2 } x25wanOperTable OBJECT-TYPE SYNTAX SEQUENCE OF X25wanOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" ::= { x25wanOper 1 } x25wanOperEntry OBJECT-TYPE SYNTAX X25wanOperEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { x25wanOperIndex } ::= { x25wanOperTable 1 } X25wanOperEntry ::= SEQUENCE { x25wanOperIndex INTEGER, x25wanOperType INTEGER, x25wanOperSpeed INTEGER, x25wanOperLinkAvailable INTEGER, x25wanOperClockSource INTEGER, x25wanOperMaxFrmSize INTEGER } x25wanOperIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { x25wanOperEntry 1 } x25wanOperType OBJECT-TYPE SYNTAX INTEGER{ rs232(1), v35(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { x25wanOperEntry 2 } x25wanOperSpeed OBJECT-TYPE SYNTAX INTEGER (0..393216) ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { x25wanOperEntry 3 } x25wanOperLinkAvailable OBJECT-TYPE SYNTAX INTEGER{ dsr(1), dcd(2) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { x25wanOperEntry 4 } x25wanOperClockSource OBJECT-TYPE SYNTAX INTEGER{ dceRxTx(1), dceRxOnly(2), brgRxTx(3) } ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { x25wanOperEntry 5 } x25wanOperMaxFrmSize OBJECT-TYPE SYNTAX INTEGER (0..519) ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { x25wanOperEntry 6 } -- The X.25 WAN Statistics Group. x25wanStats OBJECT IDENTIFIER ::= { x25w 3 } x25wanStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF X25wanStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The x25wanStatsTable is composed of counters which allow the operator to view activity which can indicate the health of the WAN connection." ::= { x25wanStats 1 } x25wanStatsEntry OBJECT-TYPE SYNTAX X25wanStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "There is one X.25 WAN status entry for each x.25 subnet installed in the NAS chassis." INDEX { x25wanStatsIndex } ::= { x25wanStatsTable 1 } X25wanStatsEntry ::= SEQUENCE { x25wanStatsIndex INTEGER, x25wanStatsGoodFramesTxs Counter, x25wanStatsGoodFramesRxs Counter, x25wanStatsTxUnderruns Counter, x25wanStatsRxOverruns Counter, x25wanStatsRxCrcErrs Counter, x25wanStatsRxFrameNoBufs Counter, x25wanStatsUnrecoveredRxs Counter, x25wanStatsRxOverflows Counter, x25wanStatsRxAborts Counter, x25wanStatsRxTooLongs Counter, x25wanStatsTxTooShorts Counter, x25wanStatsRxTooShorts Counter, x25wanStatsTxBadPackets Counter, x25wanStatsTxRingQFulls Counter, x25wanStatsRxRingQSize INTEGER, x25wanStatsDSR INTEGER, x25wanStatsCTS INTEGER, x25wanStatsDCD INTEGER } x25wanStatsIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each X25 WAN port in the NAS chassis. The value of this index matches is the entity index associated with this X25 subnet found in the USR Chassis MIB." ::= { x25wanStatsEntry 1 } x25wanStatsGoodFramesTxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of the number of good frames transmitted since this entity was initialized." ::= { x25wanStatsEntry 2 } x25wanStatsGoodFramesRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of the good frames received since this entity was intitalized." ::= { x25wanStatsEntry 3 } x25wanStatsTxUnderruns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of the number of transmit underruns that have been seen by this entity since initialization." ::= { x25wanStatsEntry 4 } x25wanStatsRxOverruns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of receiver overruns detected by this entity since intitialization." ::= { x25wanStatsEntry 5 } x25wanStatsRxCrcErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of received crc errors since this entity was intitialized." ::= { x25wanStatsEntry 6 } x25wanStatsRxFrameNoBufs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times this entity has recieved data without a buffer to place it into." ::= { x25wanStatsEntry 7 } x25wanStatsUnrecoveredRxs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of overrun frames that the entity was unable to recover." ::= { x25wanStatsEntry 8 } x25wanStatsRxOverflows OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of receive buffer overflows seen by this entity since initialization." ::= { x25wanStatsEntry 9 } x25wanStatsRxAborts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of recieve frame aborts seen by this entity since initialization." ::= { x25wanStatsEntry 10 } x25wanStatsRxTooLongs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames recieved that exceeded the defined maximum receive frame size." ::= { x25wanStatsEntry 11 } x25wanStatsTxTooShorts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times that the upper protocol layers attempted to transmit too small a frame." ::= { x25wanStatsEntry 12 } x25wanStatsRxTooShorts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of the number of frames received that were smaller than the minimum frame size." ::= { x25wanStatsEntry 13 } x25wanStatsTxBadPackets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of bad packets that the WAN interface received for transmission from the upper layers of the X.25 protocol stack." ::= { x25wanStatsEntry 14 } x25wanStatsTxRingQFulls OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A count of the number of times the circular buffer used for transmission was full when a transmission was attempted by the upper layers of the X.25 protocol stack." ::= { x25wanStatsEntry 15 } x25wanStatsRxRingQSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A number that indicates the received circular queue size on the X.25 WAN." ::= { x25wanStatsEntry 16 } x25wanStatsDSR OBJECT-TYPE SYNTAX INTEGER{ off(1), on(2) } ACCESS read-only STATUS mandatory DESCRIPTION "X.25 WAN interface DSR signal status." ::= { x25wanStatsEntry 17 } x25wanStatsCTS OBJECT-TYPE SYNTAX INTEGER{ off(1), on(2) } ACCESS read-only STATUS mandatory DESCRIPTION "X.25 WAN interface CTS signal status." ::= { x25wanStatsEntry 18 } x25wanStatsDCD OBJECT-TYPE SYNTAX INTEGER{ off(1), on(2) } ACCESS read-only STATUS mandatory DESCRIPTION "X.25 WAN interface DCD signal status." ::= { x25wanStatsEntry 19 } x25wanTrapEna OBJECT IDENTIFIER ::= { x25w 4 } x25wanTrapEnaTable OBJECT-TYPE SYNTAX SEQUENCE OF X25wanTrapEnaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The x25 WAN Trap Enable table contains an entry for each manageable X.25 Subnet in the chassis. It provides a means to enable reporting of traps associated with the subnet." ::= { x25wanTrapEna 1 } x25wanTrapEnaEntry OBJECT-TYPE SYNTAX X25wanTrapEnaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "There is one x25 WAN Cfg entry per x.25 subnet in the NAS chassis." INDEX { x25wanTrapEnaIndex } ::= { x25wanTrapEnaTable 1 } X25wanTrapEnaEntry ::= SEQUENCE { x25wanTrapEnaIndex INTEGER, x25wanTrapEnaOutOfSvc INTEGER, x25wanTrapEnaLinkActive INTEGER } x25wanTrapEnaIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each X.25 Subnet in the chassis. The value of this object matches the value of the index of the corresponding X.25 Subnet's entry in the entity table of the chassis MIB." ::= { x25wanTrapEnaEntry 1 } x25wanTrapEnaOutOfSvc OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables generation of a trap when the WAN port status changes from Link Active to Out Of Service." ::= { x25wanTrapEnaEntry 2 } x25wanTrapEnaLinkActive OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables generation of a trap when the WAN port status changes from Out Of Service to Link Active." ::= { x25wanTrapEnaEntry 3 } END